Soil Nutrient Speed Tester; BSN Series
- Soil Nutrient Stability: Absorbency of light drift<0.003
- Soil Nutrient Repeatability: Absorbency of light<0.005
- pH Testing range: 1-14
- pH Error: ±0.1
- Soil moisture Accuracy: ±2%
- Soil moisture Moisture content rate testing range: 0-100%
|
 |
Soil pH-Moisture Meter; BSPH-60
- PH range: 3‐8 PH
- Moisture range: 1‐8
|
 |
Grain Moisture Meter, BMCA-1G
- Measurement Range: 3%~35%
- Measurement Time: ≤10s
- Sample Cell: 100mL-150m
|
 |
Automatic Seed Counter, ASC-TCP
- Count Range: 0.7-12mm
- Count Accuracy: ±2‰
- Count Speed: ≥1000 /3min (Sesame)
|
 |
Seed Counter, BSCT-1
- 7-inch color touch screen to guide the operation process
- Record content: time, total number of grains, number of samples
- Adjustable speed: stepless speed regulation
- Turntable operation: automatic, jog, manual three can be converted
|
 |
Chlorophyll Meter, BCHL-B
- Min measuring interval: < 3s
- Measuring Range: 0.0-99.9 SPAD, -10~99.9°C
- Accuracy: ±3.0 SPAD; ±0.5°C
- Operating temperature: -10-50°C
|
 |
Multi-parameter Soil Moisture Meter; BAST-2G
- Small and exquisite, easy to carry and LCD display
- Both AC and DC available, internal lithium battery
- Storage capacity: up to 30,000 groups in handset, and standard equipped
with 4G Micro SD
- Synchronous detection: 32 channels to detect same time as you combine
|
 |
Illumination Chamber, ICB-L-E Series
- Volume:150L, 268L, 310L, 400L, 500L, 1000L
- Temperature range&fluctuation&uniformity:0-50°C; ±0.5℃; ±0.1°C
- Can increase the illuminance according to customer requirements
- Compressor delay protection time: About 3 min
|
 |
Weather Monitor System, Handheld Type, BAWM series
- Acquire real-time data of air temperature, humidity, light intensity, PAR,
wind direction & speed, Rainfall, CO2 concentration, soil temperature, soil
moisture, soil pH, soil salinity etc
- High precision and high accuracy
- Large LCD display, touch key
- Both AC and DC are available
- With 32 chann
|
 |
Falling Number Meter; BFLN-2 With Printer
- Electric timer: digital and precision time control
- Test results: automatically calculated by SCM, printed out by printer
- Mix stick’s weight: 25±0.05g
- Water bath barrel preheated pipe: 600W
|
 |
Grain Hardness Meter; BHDM-2
- Test range: 20kg
- Display: Digital
- Stress: Manual
- Maximum Diameter: 18mm
|
 |
Plant Porometer, PRO-1000
- Humidity: range: 0-100% RH; resolution: 0.1%; error: ≤± 1.8% RH; response
time: 15s
- Leaf temperature: range: 0-50 ℃; resolution: ≤ 0.1 ℃; error: ≤ ± 0.2 ℃
- Air temperature: range: 0-50 ℃; resolution: 0.1 ℃; error: ± 0.3 ℃
- Flowmeter: range: 0.3-1.0L/min; resolution: 0.01L/min; error: ± 2.0%
|
 |
Protable Leaf Area Meter, BLAM-1 BLAM-2
- Test unit: millimeter, square centimeter
- Precision: ±2%
- Resolution: 0.01cm2
|
 |
Climate Chamber, ICB-CC-3 Series
- Interior Volume: 175L, 275L, 375L, 475L, 800L, 1075L
- Temperature range (℃): With light:10~55℃, Without light:5~55℃
- Humidity Range: 30~95%RH
- Auxiliary temp. control and Leakage protection function
- Double door design
|
 |
Broken Rice Separator, BRS-T28
- Separation Speed: 28r/min
- Separation Quantity: 50g
- Separation Time: Set time: 2min±5s; Continue: arbitrary
- Separation Tube (Diameter* Length): 130*200mm
|
 |
Portable Area Meter, PAM-T2
- Large measurement range and precision
- Wide measurement data
- With micro-controller, high precision algorithm
|